This powerful 4-channel Analog Data Logger supports inputs from most common analog sensors, enabling seamless connection with any voltage, current, and resistive transducers.

Many supported power outputs

Can power sensors at 5V, 12V and 24V DC up to 60 mA.

Several analog input types admitted

Voltage: +/-10V, Current loop (4-20 mA), Potentiometers, Full Wheatstone bridge, Thermistor and PT-100.

Advanced setup features

Use the Worldsensing App to perform field sample collection and signal coverage testing.

Wiring assistant

On-site sensor installation is simplified with wiring recommendations provided through the Worldsensing App.

Analog Data Logger technical specifications

Channels
4 channels (isolated)
Input types
- Voltage
- Current loop
- Potentiometer
- Full wheatstone bridge
Power output per channel
5 V DC / 12 V DC / 24 V DC (up to 60 mA)
Data transmission
LoRa radio communications (ISM sub GHz)
Warmup time
Configurable (65 s MAX)
Operating temperature
-40º C to 80º C
Weather protection
IP68
Device configuration
- Worldsensing App
- CMT Edge
- CMT Cloud
Show full table +

Tailings dam safety ebook: Monitoring practices and risk management

This ebook, written by our mining and IoT experts, will help you understand the new challenges and solutions in tailings dams monitoring.

Download ebook

Analog Data Logger mounting options

Pole mounting

Using the WS-ACC-POLE-PL8 aluminum plate for pole mounting together with either WS-ACC-U35 35 mm U-bolts or WS-ACC-U50 50 mm U-bolts.

Wall mounting

Using the LS-ACC-MEC-MP external mounting brackets for wall mounting (set of 2).

For a full list of available accessories, check out the

Analog Data Logger product datasheet

Applications

Explore the wide range of monitoring solutions the Analog Data Logger enables across geotechnical, structural, environmental and remote process monitoring.

Geotechnical Monitoring

Structural Monitoring

Environmental Monitoring

Remote Process Monitoring

Pore water pressure & level

Piezometer Multi-point piezometer

Connect piezometers and multi-point piezometers from all the major geotechnical sensor manufacturers. Use 1-channel, 2-channel or 6-channel Vibrating Wire data loggers to transmit data from any number of sensor configurations. Water level sensors can be connected through Analog or Digital data loggers.

Soil water tension & moisture

Tensiometer Soil moisture sensor Granular matrix sensor

Assess soil water tension and moisture with a tensiometer and a granular matrix sensor both connected to an Analog data logger. Additionally, measure volumetric water content with a soil moisture sensor connected to a Piconode. You can also connect the Digital date logger to one or a chain of digital tensiometers.

Settlement & heave

Tiltmeter Liquid settlement system Tilt beam

Monitor settlement, heave and building response to tunneling and excavation with a liquid level settlement system connected to the Analog or the Digital data logger. Alternatively, you can use the Tiltmeter attached to a rigid beam and installed in a chain.

Specific weather parameters

Thermistor RH probe Pressure sensor Pyranometer Piconode Weather Kit

Read specific weather parameters like temperature, relative humidity, pressure or radiation through specific analog output sensors with the Analog data logger or the Piconode.

For a connect-and-collect experience, the Piconode Weather Kit offers a compact alternative. Multiple configurations are readily available, including temperature, relative humidity and rain gauge, to stream the right data to your information systems.

Open channel flow & pond level monitoring

V-notch Level sensor Vibrating wire weir

Different sensors compatible with Worldsensing data loggers can monitor flow in open channels and seepage collection ditches. For instance, non-contact level sensors using radar or ultrasonic technology can connect to the Analog data logger. Additionally, a vibrating wire weir monitor and a V-notch can measure flow in an open channel using a Vibrating Wire 1-channel data logger. Some of these sensors are also suitable for monitoring tailings pond levels.

Diesel fuel levels

Level sensor

Monitor diesel fuel levels with a fuel tank level sensor connected to an Analog data logger.

Cross-crack movements

Wireline extensometer Laser Tiltmeter Crackmeter

Detect slope movements by monitoring tension cracks across landslides using a displacement sensor compatible with Worldsensing’s Analog or Vibrating Wire data logger. For situations with large movements anticipated, wireline extensometers, draw wire sensors, or the Laser Tiltmeter can be suitable alternatives.

Loads & movement in beadings and joints

Pressure transducer Crackmeter Extensometer

Monitor the pot bearing pressure and displacement through pressure sensors, extensometers or crackmeters. Control the joint expansions and contractions wirelessly connecting these sensors to Analog, Digital or Vibrating Wire data loggers.

Frequently asked questions

What is the Analog Data Logger?

The Analog Data Logger is a wireless data acquisition IoT device that collects data from most analog signals and transmits them using long-range, low-power radio communications.

How does it work?

The Analog Data Logger operates by connecting to a specific analog sensor using any of its four different channels. It transmits data via Worldsensing LoRa networks to CMT Edge for local-access, single-network deployments. Data can also be transmitted via internet from the gateway to CMT Cloud for a multi-project, multi-network deployments.

What is the maximum interval at which data can be collected?

Devices can be configured at different reporting periods. The highest possible acquisition rate when using Worldsensing is one sample every 30 seconds, and the lowest is one sample every 24 hours. With such parameters the system can run for a long period, between 7 and 10 years.

What is the communication range for the Analog Data Logger?

The radio range of any of Loadsensing devices varies depending on the environment. In open sight, the range can reach up to 15 km (9.3 mi), while in a city street it is up to 4 km (2.5 mi). When placed in a manhole in a city street, the range is up to 2 km (1.2 mi), and in a tunnel, it extends up to 4 km (2.5 mi).

What are the maintenance and troubleshooting requirements for the Analog Data Logger? Can it be handled by skilled employees internally?

Maintenance is straightforward and varies by location. With basic training, employees can configure and maintain the devices and gateway via the Worldsensing App. Monthly visual inspections are recommended, especially in active areas. Inspect devices and sensor cables if you notice anomalous or missing readings. Our remote management software reduces manual checks by allowing 24/7 access to network status and sending downtime alerts. Batteries can last up to 10 years, but it’s best to schedule changes based on battery life estimates and data acquisition frequency.

How is the data protected during transmission?

Data protection and privacy are achieved through 128 AES [Advanced Encryption Standard] encryption on multiple levels, for all data being sent from the sensors to the application server and back.